Special Article

Effect of Bar-Code Technology on the Safety of Medication Administration

List of authors.
  • Eric G. Poon, M.D., M.P.H.,
  • Carol A. Keohane, B.S.N., R.N.,
  • Catherine S. Yoon, M.S.,
  • Matthew Ditmore, B.A.,
  • Anne Bane, R.N., M.S.N.,
  • Osnat Levtzion-Korach, M.D., M.H.A.,
  • Thomas Moniz, Pharm.D.,
  • Jeffrey M. Rothschild, M.D., M.P.H.,
  • Allen B. Kachalia, M.D., J.D.,
  • Judy Hayes, R.N., M.S.N.,
  • William W. Churchill, M.S., R.Ph.,
  • Stuart Lipsitz, Sc.D.,
  • Anthony D. Whittemore, M.D.,
  • David W. Bates, M.D.,
  • and Tejal K. Gandhi, M.D., M.P.H.

Abstract

Background

Serious medication errors are common in hospitals and often occur during order transcription or administration of medication. To help prevent such errors, technology has been developed to verify medications by incorporating bar-code verification technology within an electronic medication-administration system (bar-code eMAR).

Methods

We conducted a before-and-after, quasi-experimental study in an academic medical center that was implementing the bar-code eMAR. We assessed rates of errors in order transcription and medication administration on units before and after implementation of the bar-code eMAR. Errors that involved early or late administration of medications were classified as timing errors and all others as nontiming errors. Two clinicians reviewed the errors to determine their potential to harm patients and classified those that could be harmful as potential adverse drug events.

Results

We observed 14,041 medication administrations and reviewed 3082 order transcriptions. Observers noted 776 nontiming errors in medication administration on units that did not use the bar-code eMAR (an 11.5% error rate) versus 495 such errors on units that did use it (a 6.8% error rate) — a 41.4% relative reduction in errors (P<0.001). The rate of potential adverse drug events (other than those associated with timing errors) fell from 3.1% without the use of the bar-code eMAR to 1.6% with its use, representing a 50.8% relative reduction (P<0.001). The rate of timing errors in medication administration fell by 27.3% (P<0.001), but the rate of potential adverse drug events associated with timing errors did not change significantly. Transcription errors occurred at a rate of 6.1% on units that did not use the bar-code eMAR but were completely eliminated on units that did use it.

Conclusions

Use of the bar-code eMAR substantially reduced the rate of errors in order transcription and in medication administration as well as potential adverse drug events, although it did not eliminate such errors. Our data show that the bar-code eMAR is an important intervention to improve medication safety. (ClinicalTrials.gov number, NCT00243373.)

Introduction

Medication errors in hospitals are common1,2 and often lead to patient harm. One study identified 6.5 adverse events related to medication use per 100 inpatient admissions; more than one fourth of these events were due to errors and were therefore preventable.2 Among serious medication errors, about one third occur at the ordering stage of the medication process, another third occur during medication administration, and the remaining third occur in about equal numbers during the transcription and dispensing stages.3

Health care information technology has been touted as a promising strategy for preventing medication errors.4-6 For example, computerized physician-order entry has been shown to reduce the incidence of serious medication errors by 55%.7 Bar-code verification technology, ubiquitous in industries outside the field of health care, is another example. Previous studies have shown that this technology can prevent errors in dispensing drugs from the pharmacy8 and in counting sponges in the operative setting.9 At the bedside, the use of bar-code technology to verify a patient's identity and the medication to be administered is a promising strategy for preventing medication errors, and its use has been increasing, most notably in Veterans Affairs hospitals.10 Bar-code medication verification at the bedside is usually implemented in conjunction with an electronic medication-administration system (eMAR), allowing nurses to automatically document the administration of drugs by means of bar-code scanning. Because the eMAR imports medication orders electronically from either the physician's order entry or the pharmacy system, its implementation may reduce transcription errors. Given its potential to improve medication safety, bar-code eMAR technology is being considered as a criterion for achieving “meaningful use” of health information technology and for obtaining financial incentives under the American Recovery and Reinvestment Act of 2009 in 2013.11

Evidence of the effectiveness of the bar-code eMAR technology, however, has been limited and mixed.12-17 Moreover, several studies have highlighted certain unintended consequences of its implementation, with some users either bypassing this technology or relying on it too much, thus increasing the risk of new errors.18-22 Given the uncertainties about the bar-code eMAR technology, we evaluated its implementation in a large tertiary care medical center to assess its effects on administration and transcription errors, as well as on associated potential adverse drug events.

Methods

Overview of Bar-Code eMAR Technology

Bar-code eMAR technology incorporates several technologies into the workflow of the nursing staff to ensure that the correct medication is administered at the correct dose at the correct time to the correct patient. Traditionally, medication orders placed by physicians are manually transcribed to the paper medication-administration record, which in turn is used by nurses to determine what medications to administer and when. With the bar-code eMAR, medication orders appear on the patient's electronic record once the pharmacist has approved them. Furthermore, if a patient's medication is overdue, the nurse will be alerted through an electronic patient worklist.

In the traditional paper-driven process of administering drugs, the nurse manually verifies the dose and the patient's identity before the medication is given. Bar-code eMAR provides an additional layer of safety by requiring nurses to scan the bar codes on the patient's wristband and on the medication before it is administered. If the dose being scanned corresponds to a pharmacist-approved medication order and the patient is due for this dose, administration is automatically documented. However, if the dose does not correspond to a valid order, the application issues a warning.

For a more detailed description of how nurses use this technology and for a list of the features it supported during the study period, see Appendix A and Appendix B, respectively, in the Supplementary Appendix, available with the full text of this article at NEJM.org.

Study Design

Over a 9-month period in 2005, we determined the rate of errors related to transcribing orders and administering medications in 35 adult medical, surgical, and intensive care units in a 735-bed tertiary academic medical center. In the study year, physicians (or physician extenders) wrote approximately 1.7 million medication orders and nurses administered approximately 5.9 million doses of medications. Using a prospective, before-and-after, quasi-experimental study design, we compared error rates in units that were using the bar-code eMAR technology with the rates in units that had not implemented it.

Rollout Plan

After a brief pilot period, the hospital began implementing the bar-code eMAR technology at the bedside in April 2005. Between 2 and 4 patient-care units began using this technology every 2 weeks until, by July 2005, all 35 units had completely implemented it. Before each period of rollout, nurses received 4 hours of hands-on classroom training in medication scanning and use of the eMAR application. During the 2-week rollout period, the hospital provided specially trained nurses during all nursing shifts on the participating units to support the nurses who were learning to use the new technology. The hospital's information systems department also provided continuous onsite support during the rollout period.

The clinical decision was made to delay the rollout of the bar-code eMAR technology on oncology units because of the complex protocols, dosing regimens, and specialized workflow for administering medications to these patients. Therefore, these units were not included in the study.

Study Outcomes

We defined two main outcomes for administration errors: errors in timing (involving administrations that were early or late by more than 1 hour) and errors unrelated to timing. These two outcomes were defined separately because there was no broad agreement in the literature regarding what constitutes an early or a late medication administration. The unit of analysis for administration errors was the presence or absence of an error in the dose of medication administered during the observation period; the unit of analysis for transcription errors was the presence or absence of an error in the transcribed medication order.

Data Collection and Adjudication

Trained research nurses directly observed order transcription and medication administration in each study unit 2 to 4 weeks before the bar-code eMAR rollout and then 4 to 8 weeks afterward. Because of the staggered nature of the rollout, observations were made simultaneously in units with and those without the bar-code eMAR during approximately half the observation period, which lasted from February through October 2005.

We used a direct-observation method to measure error rates.23 Research nurses shadowed staff nurses on the observation units for 4 hours and, without knowing the physician's medication orders, recorded details about the medications being administered to patients. On the rare occasion when a research nurse believed that a medication was being administered erroneously by a staff nurse, the research nurse intercepted the administration and recorded that attempt as an administration error. After completing the observation session, the research nurses, assisted by research pharmacists, reviewed the physicians' orders and either the paper record of medication administration (on units without the bar-code eMAR) or the eMAR (on units with the bar-code eMAR). Using these documents, they determined whether there were any transcription errors (i.e., errors in the transcription of physicians' orders for medications administered during the observation period) or any administration errors (i.e., errors in administering medications, based on what the nurses had directly observed).

Each administration error and transcription error was classified by a member of the study staff according to the type of error (Appendix C in the Supplementary Appendix). Each error was further adjudicated independently by two members of a multidisciplinary panel consisting of physicians, nurses, and pharmacists to confirm the presence of an error and the potential for that error to lead to patient harm (a subgroup known as potential adverse drug events). Harm was further classified as clinically significant, serious, or life-threatening.24 Any disagreements between the two panel members concerning the presence of an error or the severity of potential harm were resolved by consensus.

Statistical Analysis

Rates of administration errors related to timing, those unrelated to timing, and transcription errors were compared between units with the bar-code eMAR and those without it. Unadjusted error rates were compared with the use of the Rao–Scott chi-square test,25 accounting for clustering by nurse (i.e., multiple observations of medications administered by the same nurse). To adjust for possible confounders, such as unit type, we built clustered logistic-regression models26 with presence of error as the dependent variable. Statistical analyses were performed with the use of SAS software, version 9.1 (SAS Institute).

Results

Table 1. Table 1. Characteristics of 14,041 Observed Medication Administrations and 1726 Patients on Hospital Unitswith and Those without the Bar-Code eMAR.

We observed 6723 medication administrations on patient units that did not have bar-code eMAR and 7318 medication administrations on patient units that did. Most of the observations occurred during a weekday nursing shift (7 a.m. to 3 p.m.). Table 1 lists the types of medications for which administration was observed and the characteristics of the patients who received them.

Nontiming Errors in Medication Administration

Table 2. Table 2. Nontiming Medication-Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.

On units without the bar-code eMAR, we observed 776 nontiming medication-administration errors (an 11.5% error rate), whereas on units with the bar-code eMAR, we observed 495 nontiming medication-administration errors (a 6.8% error rate), representing a 41.4% relative reduction in the rate of such errors (P<0.001) (Table 2). The rate of potential adverse drug events due to nontiming administration errors fell from 3.1% to 1.6%, representing a 50.8% relative reduction (P<0.001). Significant reductions were seen in potential adverse drug events with a severity rating of significant (a 48.5% reduction) or serious (a 54.1% reduction); the rate of potential adverse drug events that were life-threatening did not change significantly.

We observed significant relative reductions in many subtypes of nontiming medication-administration errors, including those that the bar-code eMAR was expected to reduce. For example, wrong-medication errors were reduced by 57.4%, wrong-dose errors by 41.9%, and administration-documentation errors by 80.3%. There were significant reductions in potential adverse drug events associated with administration-documentation errors (80.3% reduction) and wrong-dose errors (33.0% reduction).

Significant reductions were seen in rates of nontiming administration errors and of associated potential adverse drug events on the surgical units (44.9% and 56.1%, respectively; P<0.001 for both) and on the intensive care units (42.5% [P=0.001] and 69.3% [P<0.001]). On the medical units, which had the lowest error rate at baseline among the three types of units, the rate of medical errors was reduced by 25.1% (P=0.03), but the rate of potential adverse drug events was reduced by only 11.1% (P=0.59).

Timing Errors in Medication Administration

Table 3. Table 3. Timing Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.

The overall incidence of medication doses directly observed to be administered either early or late decreased from 16.7% without the bar-code eMAR to 12.2% with its use (a reduction of 27.3%; P=0.001) (Table 3). The majority of these errors were due to administrations that were late by 1 to 2 hours, which fell by 23.9% with use of the bar-code eMAR. The incidence of potential adverse drug events due to late or early administration did not differ significantly between the units with and those without the bar-code eMAR technology.

Transcription Errors

Table 4. Table 4. Transcription Errors, Medication Errors, and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR for 3082 Orders Reviewed.

We reviewed 1799 orders on units without the bar-code eMAR and observed 110 transcription errors, of which 53 were potential adverse drug events, corresponding to 6.1 transcription errors and 2.9 potential adverse drug events per 100 medication orders transcribed (Table 4). In the 1283 medication orders reviewed on units with the bar-code eMAR, no transcription errors occurred (P<0.001 for transcription errors and for potential adverse drug events due to such errors, by Fisher's exact test).

Errors intercepted by the bar-code eMAR during the 2 years after the implementation period are shown in Appendix D in the Supplementary Appendix.

Discussion

The implementation of bar-code medication-verification technology embedded in an eMAR was associated with a 41% reduction in nontiming administration errors and a 51% reduction in potential adverse drug events from these errors. Errors in the timing of medication administration fell by 27%, although we did not see any significant change in associated potential adverse drug events. Transcription errors and associated potential adverse drug events were essentially eliminated. Because the study hospital administers approximately 5.9 million doses of medications per year, use of the bar-code eMAR is expected to prevent approximately 95,000 potential adverse drug events at the point of medication administration every year in this hospital. The technology is also expected to reduce the number of late or early administrations by about 270,000 per year. Given that the electronic order-entry system at the study hospital processed about 1.69 million medication orders during the study year, the eMAR system is also expected to prevent approximately 50,000 potential adverse drug events related to transcription errors.

Although pharmacists and nurses often intercept errors during the medication-ordering stage, errors made during the administration stage and, to a lesser extent, during the medication-transcription stage often go undetected.3 This finding highlights the need for highly reliable strategies such as bar-code technology to act as an additional safety net in medication administration. The close integration of the order-entry, pharmacy, and medication-administration systems ensures that nurses administer medications only after pharmacists have clinically reviewed the medication orders (except for medications used in emergencies), allowing patients to benefit more fully from pharmacists' clinical knowledge. Preventing transcription errors is also important, especially since each erroneous transcription can lead to repeated erroneous administrations. Given the high number of doses administered and orders transcribed in any acute care hospital, implementation of the bar-code eMAR could substantially improve medication safety.

Figure 1. Figure 1. Effect of Health Information Technology at Key Stages in the Process of Medication Use.

Data on errors during the four phases of medication use are from Leape et al.3 The percent reduction in ordering errors with the use of computerized physician-order entry (CPOE) is from Bates et al.7 The percent reduction in dispensing errors with bar-code scanning in the pharmacy is from our previous study.8 The percent reduction in medication-administration errors with the bar-code eMAR technology and the percent reduction in transcribing errors are from the current study.

The effect of the bar-code eMAR in our study was similar to the effect of the early implementation of computerized physician-order entry, which reduced serious medication errors at the ordering stage by 55%.7 Decision support embedded within computerized physician-order entry systems is more likely to prevent errors that result from bad judgment, insufficient knowledge, or incomplete clinical information when choosing a therapeutic plan; in contrast, the bar-code eMAR system is more likely to prevent errors associated with memory lapses or mental slips in executing a therapeutic plan. As such, the two technologies would probably play complementary roles in improving medication safety in acute care hospitals. Further research is needed to determine the relative values of computerized physician-order entry and the bar-code eMAR system when resources do not permit a particular hospital to implement the two technologies simultaneously. The proportion of serious medication errors committed and the magnitude of the reduction in serious errors by health information technology at the four stages of the inpatient medication process may inform that line of research (Figure 1).

Our study suggests that the prevention of many of the potential adverse drug events could be attributed to the reduction in documentation errors. This finding may lead some to conclude that the eMAR component of the bar-code eMAR may have greater effect than the medication-verification component. However, our experience in studying the workflow of the medication-administration process suggests that the medication-verification component greatly facilitates the documentation process for nurses and may be an important factor for its acceptance.27 Previous research in human-factors engineering also suggests that new errors may be introduced if busy clinicians are asked to select medications from a list of multiple medications due to be administered and then to document the administration times using a keyboard and a mouse.28,29 In addition, by the time we conducted the current study, our study hospital had already implemented bar-code verification in the pharmacy, resulting in significantly fewer wrong medications found in the areas where medications are stored.8 Our results likely represent a lower boundary with respect to the effect of the medication-verification step. Further study may be necessary to address the relative importance of the two main components of the bar-code eMAR.

Although the rate of medication-administration errors fell substantially, not all errors were eliminated. There are two possible reasons for this. First, patient-safety technology is effective only if it is used as intended. Even though the study hospital expended substantial resources in the training of end users, 20% of the drugs administered on units with the bar-code eMAR technology were given without the bar-code scanning step during the study period; this rate of noncompliance might be due in part to the learning curve in the early stages of implementation. Second, the study hospital used an early version of the software; several important improvements have been incorporated since this study was carried out, including improved functionality for intravenous medication administration, sliding-scale dosing, fractional dosing, and nonstandard scheduling of doses. These issues illustrate that the deployment of health information technology should be thought of not as a single event in time but rather as an iterative process that requires modifications and improvements.

This study has several limitations. First, the results reflect the experience of one hospital that already has fully implemented computerized physician-order entry for physicians and bar-code verification for pharmacy staff. Hospitals that choose to implement the bar-code eMAR technology without computerized physician-order entry, pharmacy bar-code verification, or both may find that it has a different effect on administration errors. For example, hospitals without computerized physician-order entry will probably not eliminate transcription errors. Second, the study examined potential adverse drug events, not actual adverse drug events. Although an earlier study estimated that one actual adverse drug event occurs for every seven potential events,30 further research will be needed to determine the true effect of the bar-code eMAR on adverse drug events. Third, the study hospital designed the application in close collaboration with users and clinical leaders who were willing to support a substantial change in workflow to improve the overall medication process. In addition, extensive resources were expended to support the rollout, including adequate training, onsite support, adequate hardware, and a responsive software-development team. Organizations interested in implementing the bar-code eMAR should consider these factors in order to maximize their investment in this patient-safety technology, and future studies should evaluate vendor solutions implemented in the community setting. Fourth, the nurses observed in this study might have performed better because they were being watched (a phenomenon known as the Hawthorne effect); however, this effect probably applied equally to observations made or units with and without bar-code eMAR technology. Previous studies have also suggested that the Hawthorne effect is minimal after the subject is initially exposed to the observer.31 Fifth, even though observations were made simultaneously on the units with the bar-code eMAR and on those without it for part of the study period, the staggered rollout schedule meant that more observations were made on units without the bar-code eMAR during the early part of the study period. Our findings might therefore have been subject to a secular effect, although it is unlikely that this effect would have been substantial over a period of 9 months.

Taken together, our findings show that the bar-code eMAR technology improves medication safety by reducing administration and transcription errors, providing support for the inclusion of this technology as a 2013 criterion for achieving meaningful use under the American Recovery and Reinvestment Act. Given challenges in implementing this technology, however, further research should focus on identifying factors that will lead to its optimal implementation.

Funding and Disclosures

Supported by a grant (HS14053-02) from the Agency for Healthcare Research and Quality.

Disclosure forms provided by the authors are available with the full text of this article at NEJM.org.

We thank Erica Featherstone for her assistance with data management; Erin Hartman for her editorial assistance; Sue Schade, chief information officer at the study hospital, for providing a list of features of the bar-code eMAR system available at the time of the study; and Micheal Sweet for providing data on warnings issued by the system after the initial implementation period.

Author Affiliations

From Brigham and Women's Hospital (E.G.P., C.A.K., C.S.Y., M.D., A.B., O.L.-K., T.M., J.M.R., A.K., J.H., W.W.C., S.L., A.D.W., D.W.B., T.K.G.); Harvard Medical School (E.G.P., J.M.R., A.B.K., A.D.W., D.W.B., T.K.G.); Partners Information Systems (E.G.P., D.W.B.); and Faulkner Hospital (J.H.) — all in Boston.

Address reprint requests to Dr. Poon at the Division of General Medicine Primary Care, Brigham and Women's Hospital, 3/F, 1620 Tremont St., Boston, MA 02120, or at .

Supplementary Material

References (31)

  1. 1. Brennan TA, Leape LL, Laird NM, et al. Incidence of adverse events and negligence in hospitalized patients. N Engl J Med 1991;324:370-376

  2. 2. Bates DW, Cullen DJ, Laird N, et al. Incidence of adverse drug events and potential adverse drug events. JAMA 1995;274:29-34

  3. 3. Leape LL, Bates DW, Cullen DJ, et al. Systems analysis of adverse drug events: ADE Prevention Study Group. JAMA 1995;274:35-43

  4. 4. Bates DW. Using information technology to reduce rates of medication errors in hospitals. BMJ 2000;320:788-791

  5. 5. CPOE, bedside technology, and patient safety: a roundtable discussion. Am J Health Syst Pharm 2003;60:1219-1228

  6. 6. Bates DW, Gawande AA. Improving safety with information technology. N Engl J Med 2003;348:2526-2534

  7. 7. Bates DW, Leape LL, Cullen DJ, et al. Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA 1998;280:1311-1316

  8. 8. Poon EG, Cina JL, Churchill W, et al. Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy. Ann Intern Med 2006;145:426-434

  9. 9. Greenberg CC, Diaz-Flores R, Lipsitz SR, et al. Bar-coding surgical sponges to improve safety: a randomized controlled trial. Ann Surg 2008;247:612-616

  10. 10. Wright AA, Katz IT. Bar coding for patient safety. N Engl J Med 2005;353:329-331

  11. 11. Health IT Policy Committee. Final meaningful use objectives and measures: 2011–2013–2015. Washington, DC: Department of Health and Human Services, Office of the National Coordinator for Health Information Technology, 2009. (Accessed April 9, 2010, at http://healthit.hhs.gov/portal/server.pt/gateway/PTARGS_0_10741_888532_0_0_18/FINAL%20MU%20RECOMMENDATIONS%20TABLE.pdf.)

  12. 12. Johnson CL, Carlson RA, Tucker CL, Willette C. Using BCMA software to improve patient safety in Veterans Administration medical centers. J Healthc Inf Manag 2003;16:46-51

  13. 13. Puckett F. Medication-management component of a point-of-care information system. Am J Health Syst Pharm 1995;52:1305-1309

  14. 14. Yang M, Brown M, Trohimovich B, Dana M, Kelly J. The effect of bar-code enabled point-of-care technology on medication administration errors. In: Lewis R, ed. The impact of information technology on patient safety. Chicago: Healthcare Information and Management Systems Society, 2002:37-56.

  15. 15. Paoletti RD, Suess TM, Lesko MG, et al. Using bar-code technology and medication observation methodology for safer medication administration. Am J Health Syst Pharm 2007;64:536-543

  16. 16. Franklin B, O'Grady K, Donyai P, Jacklin A, Barber N. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors, and staff time: a before-and-after study. Qual Saf Health Care 2007;16:279-284

  17. 17. Mahoney CD, Berard-Collins CM, Coleman R, Amaral JF, Cotter CM. Effects of an integrated clinical information system on medication safety in a multi-hospital setting. Am J Health Syst Pharm 2007;64:1969-1977

  18. 18. Patterson ES, Cook RI, Render ML. Improving patient safety by identifying side effects from introducing bar coding in medication administration. J Am Med Inform Assoc 2002;9:540-553

  19. 19. McDonald CJ. Computerization can create safety hazards: a bar-coding near miss. Ann Intern Med 2006;144:510-516[Erratum, Ann Intern Med 2006;145:235.]

  20. 20. Cochran GL, Jones KJ, Brockman J, Skinner A, Hicks RW. Errors prevented by and associated with bar-code medication administration systems. Jt Comm J Qual Patient Saf 2007;33:293-301

  21. 21. DiConsiglio J. Creative `work-arounds' defeat bar-coding safeguard for meds: study finds technology often doesn't meet the needs of nurses. Mater Manag Health Care 2008;17:26-29

  22. 22. Koppel R, Wetterneck T, Telles JL, Karsh BT. Workarounds to barcode medication administration systems: their occurrences, causes, and threats to patient safety. J Am Med Inform Assoc 2008;15:408-423

  23. 23. Barker KN, Flynn EA, Pepper GA, Bates DW, Mikeal RL. Medication errors observed in 36 health care facilities. Arch Intern Med 2002;162:1897-1903

  24. 24. Folli HL, Poole RL, Benitz WE, Russo JC. Medication error prevention by clinical pharmacists in two children's hospitals. Pediatrics 1987;79:718-722

  25. 25. Rao JNK, Scott AJ. On simple adjustments to chi-square tests with sample survey data. Ann Stat 1987;15:385-397

  26. 26. Zeger SL, Liang KY. Longitudinal data analysis for discrete and continuous outcomes. Biometrics 1986;42:121-130

  27. 27. Poon EG, Keohane CA, Bane A, et al. Impact of barcode medication administration technology on how nurses spend their time providing patient care. J Nurs Adm 2008;38:541-549

  28. 28. Koppel R, Metlay JP, Cohen A, et al. Role of computerized physician order entry systems in facilitating medication errors. JAMA 2005;293:1197-1203

  29. 29. Woods DD, Patterson ES, Cook RI. Behind human error: taming complexity to improve patient safety. In: Carayon P, ed. Handbook of human factors and ergonomics in health care and patient safety. Mahwah, NJ: Lawrence Erlbaum Associates, 2007:459-76.

  30. 30. Bates DW, Boyle DL, Vander Vliet MB, Schneider J, Leape L. Relationship between medication errors and adverse drug events. J Gen Intern Med 1995;10:199-205

  31. 31. Flynn EA, Barker KN. Medication error research. In: Cohen MR, ed. Medication errors: causes and prevention. Washington, DC: American Pharmaceutical Association, 1999.

Citing Articles (334)

    Figures/Media

    1. Table 1. Characteristics of 14,041 Observed Medication Administrations and 1726 Patients on Hospital Unitswith and Those without the Bar-Code eMAR.
      Table 1. Characteristics of 14,041 Observed Medication Administrations and 1726 Patients on Hospital Unitswith and Those without the Bar-Code eMAR.
    2. Table 2. Nontiming Medication-Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.
      Table 2. Nontiming Medication-Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.
    3. Table 3. Timing Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.
      Table 3. Timing Administration Errors and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR.
    4. Table 4. Transcription Errors, Medication Errors, and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR for 3082 Orders Reviewed.
      Table 4. Transcription Errors, Medication Errors, and Potential Adverse Drug Events on Units without and Those with the Bar-Code eMAR for 3082 Orders Reviewed.
    5. Figure 1. Effect of Health Information Technology at Key Stages in the Process of Medication Use.
      Figure 1. Effect of Health Information Technology at Key Stages in the Process of Medication Use.

      Data on errors during the four phases of medication use are from Leape et al.3 The percent reduction in ordering errors with the use of computerized physician-order entry (CPOE) is from Bates et al.7 The percent reduction in dispensing errors with bar-code scanning in the pharmacy is from our previous study.8 The percent reduction in medication-administration errors with the bar-code eMAR technology and the percent reduction in transcribing errors are from the current study.