Join the 200th Anniversary Celebration

Original Article

Fetal Pulse Oximetry and Cesarean Delivery

Steven L. Bloom, M.D., Catherine Y. Spong, M.D., Elizabeth Thom, Ph.D., Michael W. Varner, M.D., Dwight J. Rouse, M.D., Sandy Weininger, Ph.D., Susan M. Ramin, M.D., Steve N. Caritis, M.D., Alan Peaceman, M.D., Yoram Sorokin, M.D., Anthony Sciscione, M.D., Marshall Carpenter, M.D., Brian Mercer, M.D., John Thorp, M.D., Fergal Malone, M.D., Margaret Harper, M.D., Jay Iams, M.D., and Garland Anderson, M.D. for the National Institute of Child Health and Human Development Maternal–Fetal Medicine Units Network

N Engl J Med 2006; 355:2195-2202November 23, 2006

Abstract

Background

Knowledge of fetal oxygen saturation, as an adjunct to electronic fetal monitoring, may be associated with a significant change in the rate of cesarean deliveries or the infant's condition at birth.

Methods

We randomly assigned 5341 nulliparous women who were at term and in early labor to either “open” or “masked” fetal pulse oximetry. In the open group, fetal oxygen saturation values were displayed to the clinician. In the masked group, the fetal oxygen sensor was inserted and the values were recorded by computer, but the data were hidden. Labor complicated by a nonreassuring fetal heart rate before randomization was documented for subsequent analysis.

Results

There was no significant difference in the overall rates of cesarean delivery between the open and masked groups (26.3% and 27.5%, respectively; P=0.31). The rates of cesarean delivery associated with the separate indications of a nonreassuring fetal heart rate (7.1% and 7.9%, respectively; P=0.30) and dystocia (18.6% and 19.2%, respectively; P=0.59) were similar between the two groups. Similar findings were observed in the subgroup of 2168 women in whom a nonreassuring fetal heart rate was detected before randomization. The condition of the infants at birth did not differ significantly between the two groups.

Conclusions

Knowledge of the fetal oxygen saturation is not associated with a reduction in the rate of cesarean delivery or with improvement in the condition of the newborn. (ClinicalTrials.gov number, NCT00098709.)

Media in This Article

Figure 1Screening, Enrollment, and Randomization.
Table 1Characteristics of the 5341 Nulliparous Women Enrolled in the Study.
Article

In 2003, electronic fetal monitoring was used during approximately 3.2 million labors in the United States, accounting for 85% of all live births and making it the most common obstetrical procedure performed in this country.1 Despite its widespread use, there is controversy about the interpretation and efficacy of electronic fetal monitoring.2 For example, some people believe that the use of electronic fetal monitoring to detect a nonreassuring fetal heart rate is one of the many factors contributing to the escalating rate of cesarean delivery in the United States, which by 2004 had reached nearly 30%.3

In May 2000, the Food and Drug Administration (FDA) granted conditional approval of the OxiFirst Fetal Oxygen Saturation Monitoring System for use as an adjunct to electronic fetal monitoring.4 This new technology was designed to improve knowledge of the fetal condition by continuously measuring fetal oxygen saturation in the presence of a nonreassuring fetal heart-rate pattern. With this technology, a specialized sensor is inserted through the dilated cervix after the membranes have ruptured and is positioned against the fetal face. Once in contact with the fetal skin, the device permits measurement of fetal oxygen saturation during labor.5

Conditional approval of the device was based primarily on the results of a trial6 in which 1010 women with labors complicated by nonreassuring fetal heart-rate patterns were randomly assigned to either electronic fetal monitoring alone or electronic fetal monitoring plus continuous fetal pulse oximetry. The use of fetal oximetry was associated with a reduction in the rate of cesarean delivery for the indication of a nonreassuring fetal heart rate from 10.2 to 4.5% (P=0.007). However, the rate of cesarean delivery for the indication of dystocia in the oximetry group more than doubled, resulting in no overall difference in the rate of cesarean delivery between the two groups. The discrepancy in the effect of the oximeter between the two indications for cesarean delivery was unanticipated and not easily explained.6,7

Although the reduction in cesarean deliveries for the indication of a nonreassuring fetal heart rate was promising,6 the results raised several questions. Was this discrepancy in the effect of the oximeter according to the indication for cesarean delivery reproducible? Was the sample size adequate to permit assessment of infant safety in instances when an obstetrician withholds cesarean delivery in the presence of an abnormal fetal heart rate because fetal oxygenation is deemed to be normal? Concerns such as these prompted the American College of Obstetricians and Gynecologists to withhold endorsement of the oximeter for use in clinical practice until additional studies were conducted.8 Similarly, FDA approval was contingent on the results of postapproval studies.4

We designed a randomized trial to evaluate the effectiveness and safety of fetal oximetry. The primary objective was to determine whether fetal oximetry, as an adjunct to conventional electronic fetal monitoring, would result in a reduction in the overall rate of cesarean deliveries. We also assessed whether knowledge of fetal oxygen saturation changed the rate of cesarean delivery for the indications of nonreassuring fetal heart rate and dystocia and evaluated the potential side effects of such monitoring in both the mother and the neonate.

Methods

The National Institute of Child Health and Human Development Maternal–Fetal Medicine Units Network conducted the trial. The network was established in 1986 to study clinical questions in obstetrics. At the time of this trial, the network consisted of 14 university-based clinical centers and an independent data-coordinating center. The study was approved by the institutional review board at each participating center and was conducted under an investigational-device exemption granted by the FDA. Written informed consent was obtained from all study participants.

Training Phase

Two centralized training sessions were conducted, which included didactic instruction as well as hands-on training with the study equipment. Additional training was performed at each site by educators from Nellcor Puritan Bennett, the manufacturer of the fetal pulse oximeter. The training included instruction on the recommended interpretation of values for fetal oxygen saturation.6 Before a center was authorized to begin recruitment, attending physicians and research nurses had to pass both written and practical examinations for certification. Once they were trained and certified, research nurse coordinators could train additional personnel at a later date, who in turn had to become certified to participate in the study. A mandated refresher training course was conducted after 2 years.

Equipment

Study equipment included an electronic fetal monitor (Corometrics Model 128 Basic Maternal Fetal Monitor, GE Healthcare), a fetal pulse oximeter (Nellcor OxiFirst N-400, Mallinckrodt), and a laptop computer. These components were customized to interface with one another and to permit masking of the values for fetal oxygen saturation in the control group. The equipment was also configured such that time-posted fetal heart rate, uterine contractions, and fetal oxygen saturation could be electronically archived. None of the manufacturers of these products provided financial support or had any role in the design, conduct, interpretation, or reporting of this study.

Protocol

We screened nulliparous women presenting to a labor-and-delivery unit at any of the participating centers who had a singleton, cephalic, living fetus at or beyond 36 weeks of gestation. Exclusion criteria were a planned cesarean delivery, maternal fever (body temperature of at least 38°C), known human immunodeficiency virus or hepatitis virus infection, heart or renal disease, and diabetes mellitus. Women who were screened and whose examination showed cervical dilatation between 2 cm and 6 cm were eligible for randomization.

Data on fetal heart-rate patterns before randomization were collected to allow stratification of our study population into two groups — one group with nonreassuring fetal heart-rate patterns (the group for which the fetal oximeter was primarily intended) and the other without fetal heart-rate abnormalities before the time of randomization. Nonreassuring fetal heart-rate patterns were defined according to the following criteria, used by Garite and colleagues6 in an earlier trial of fetal oximetry: severe variable decelerations (<70 beats per minute for at least 60 seconds), late decelerations, bradycardia (<110 beats per minute), tachycardia (>160 beats per minute), diminished heart-rate variability (<5 beats per minute over a period of at least 30 minutes), one or more variable decelerations in two consecutive 30-minute windows, increased heart-rate variability (>25 beats per minute over a period of 30 minutes), baseline rate of at least 100 to 120 beats per minute without accelerations, or suspected fetal arrhythmia. The principal investigator or an alternate investigator at each site reviewed all tracings.

After the placement of an internal electronic fetal heart-rate monitor and intrauterine pressure catheter, fetal oxygen sensors were applied by certified personnel. If three attempts at insertion were unsuccessful or if signal registration had not been accomplished after 15 minutes, the attempt at sensor insertion was declared to be unsuccessful, and the patient did not undergo randomization.

After successful placement of the sensors, randomization was performed by a research nurse through an encrypted program in the laptop computer. In the masked mode, no saturation values were displayed on the oximeter or printed on the paper tracing from the fetal heart-rate monitor. However, the signal strength was displayed on the oximeter so that the research nurse could adjust the sensor to maintain adequate contact with the fetus but could not see the actual saturation values. The status of the device — masked or not — was continuously recorded so that the integrity of the randomization assignment could be validated.

Intrapartum management in both groups was left to the discretion of the attending physician. A research nurse was present throughout labor to adjust the sensor as needed and at delivery to evaluate the newborn for facial marks from the sensor and to confirm the indication for cesarean delivery, if performed.

Detailed information regarding the medical and obstetrical history, intrapartum course, postpartum complications diagnosed before hospital discharge, and the infant's condition was abstracted from maternal and infant charts by certified research nurses. In cases in which the initial maternal chart review indicated a diagnosis of placental abruption or prolonged fetal heart-rate decelerations at the time of sensor insertion, charts were reviewed by one of the investigators for confirmation. Similarly, neonatal charts were reviewed by an investigator for confirmation if any of the following was reported: death, a diagnosis of hypoxic–ischemic encephalopathy, seizure, cardiopulmonary resuscitation during the first 24 hours of life, head imaging, an umbilical-artery blood pH value below 7.0, the need for a ventilator, intubation at delivery, admission to the neonatal intensive care unit (NICU) for at least 14 days, or a 5-minute Apgar score of less than 4. Chart reviewers had no knowledge of the randomization assignment.

The composite outcome, defined to address fetal safety, consisted of any of the following: a 5-minute Apgar score of less than 4, an umbilical-artery blood pH value below 7.0, seizures, intubation in the delivery room, stillbirth, neonatal death, or admission to the NICU for more than 48 hours. Hypoxic–ischemic encephalopathy was diagnosed if the umbilical-artery blood pH was below 7.0, seizure occurred during the newborn period, and there was evidence of multiorgan dysfunction.

Statistical Analysis

On the basis of data from one of the centers, we projected that the group in which values for fetal oxygen saturation were not displayed (the “masked” group) would have an overall rate of cesarean delivery of at least 15% and a 4% rate of cesarean delivery because of a nonreassuring fetal heart rate. Therefore, the enrollment of 10,000 patients was calculated to provide the study with a statistical power of almost 90% to detect a 15% reduction in cesarean delivery and to have 90% power to detect a 30% reduction in cesarean delivery because of a nonreassuring fetal heart rate, with a two-sided type I error rate of 5%. Moreover, it was expected that about one third of patients would have nonreassuring fetal heart-rate patterns at entry and that the enrollment of 10,000 would provide a statistical power of more than 90% to detect a 20% reduction in the overall rate of cesarean delivery in that group. This sample size resulted in similar power to detect a 50% increase in the composite neonatal outcome in the group in which values for fetal oxygen saturation were displayed (the “open” group).

Before the trial began, we decided that the independent data and safety monitoring committee would use the group sequential method of Lan and DeMets,9 with a spending function for the type I error corresponding to the O'Brien–Fleming boundary for interim monitoring. The final analysis was performed according to the intention-to-treat principle. Continuous variables were compared by means of the Wilcoxon rank-sum test, and categorical variables were compared by means of the chi-square or Fisher's exact test, as appropriate.

Results

Recruitment began in May 2002. At the third interim analysis, on the basis of data from 5017 women, the data and safety monitoring committee concluded that an adequate number of subjects had already been enrolled to address the major study outcomes. This conclusion was based on the fact that the primary outcome, the rate of cesarean delivery, was higher than expected (27.4% instead of 15.0%), so that there was already 90% power to detect a 15% reduction in the primary outcome. The committee noted that secondary outcomes were also more frequent than projected and that there was adequate power (86 to 92%) to detect the prespecified differences. An additional 324 women had been recruited by the time the decision was made to stop the study in February 2005.

A total of 27,571 women were screened, of whom 10,589 were excluded and 11,429 declined participation (Figure 1Figure 1Screening, Enrollment, and Randomization.). An additional 170 women underwent failed attempts at sensor insertion, and attempts were abandoned in another 42 women, who had prolonged fetal heart-rate decelerations during sensor insertion. Of the remaining 5341 women, 2629 were randomly assigned to the open group, and 2712 to the masked group.

Of the 5341 women in the final study cohort, 18 had no fetal oxygen-saturation values recorded after randomization (7 in the open group and 11 in the masked group). In another five women assigned to the masked group, fetal oxygen-saturation values were inadvertently displayed. The oxygen sensor was removed before completion of the study in 238 women in the open group and 267 women in the masked group for the following reasons: patient's request (244 women), physician's request (196), and technical problems (65). Discomfort accounted for 91.8% of the patients' requests for sensor removal, and interference with the cervical examination or management of late labor accounted for 66.8% of the physicians' requests.

Characteristics of the women who underwent randomization are summarized in Table 1Table 1Characteristics of the 5341 Nulliparous Women Enrolled in the Study.. The median percentages of time that oxygen-saturation values were recorded in the open and masked groups were 75.2% and 72.9%, respectively.

Intrapartum outcomes for all women enrolled in the study are shown in Table 2Table 2Intrapartum Outcomes According to Study Group Assignment.. There were no significant differences between the two study groups in the overall rates of cesarean delivery or forceps or vacuum-assisted vaginal delivery. Specifically, the relative risk of cesarean delivery associated with knowledge of fetal oxygen saturation was 0.96 (95% confidence interval [CI], 0.87 to 1.04). These results were not materially changed when women in whom labor was induced were excluded (data not shown). The rates of cesarean delivery also did not differ significantly between the groups in an analysis limited to the 2168 women who had a nonreassuring fetal heart rate before randomization (Table 2).

Maternal and infant complications did not differ significantly between the study groups (Table 3Table 3Maternal and Infant Outcomes.). There was one neonatal death due to sepsis in the masked group. Similar proportions of infants in each group had facial marks from the sensor, and in 86.6% of these infants, the marks resolved by 24 hours of age. There was no significant difference in the time from randomization to delivery between the two groups. Among the 5553 women in whom sensor placement was attempted (Figure 1), prolonged fetal heart-rate decelerations (less than 100 beats per minute for 2 or more minutes) during insertion developed in 54 women (12 who were randomly assigned to a study group and 42 who were not). Of these 54 women, 14 (25.9%) underwent immediate cesarean delivery and the fetuses of 28 (51.9%) had nuchal cords at birth. Uterine perforation or placental abruption, possibly associated with insertion of the sensor, did not occur.

The sensitivity, specificity, and positive and negative predictive values of nonreassuring fetal heart-rate patterns for low oxygen saturation (less than 30% for at least 2 consecutive minutes)10 were 86.7%, 19.5%, 34.6%, and 74.9%, respectively (Table 4Table 4Relationship between Nonreassuring Fetal Heart-Rate Tracings and Low Oxygen Saturation.). Of note, 34.6% of the nonreassuring patterns, but also 25.1% of the normal patterns, were associated with low oxygen saturation.

Discussion

In this study of more than 5000 women delivering at 14 university hospitals throughout the United States, knowledge of intrapartum fetal oxygen saturation had no significant effect on the rates of cesarean delivery overall or specifically for the indications of a nonreassuring fetal heart rate or dystocia. In addition, knowledge of fetal oxygen saturation did not significantly affect infant outcomes. Findings for the subgroup of women with fetal heart-rate abnormalities before randomization were similar to those for the overall cohort.

Low oxygen saturation, although common in women with fetal heart-rate abnormalities, was also quite frequent in women with normal fetal heart-rate patterns. These results may explain our finding that fetal oximetry was of no benefit as an adjunct for the interpretation of electronic fetal heart-rate patterns.

Prolonged fetal heart-rate decelerations during sensor insertion occurred in 54 women. We considered the possibility that this complication was provoked by direct impingement of the sensor on the umbilical cord or by manipulation of the fetal head during insertion of the sensor. Indeed, 52% of the cases were associated with a nuchal cord. This rate is approximately double the expected incidence among all babies delivered.11 Other than the unusual case of an abnormal fetal heart rate temporally related to sensor insertion, measuring fetal oxygen saturation and providing this information to clinicians had no discernible beneficial or harmful effects.

There are both similarities and differences between our findings and those previously reported by Garite and colleagues.6 Neither study showed any significant change in the overall rate of cesarean delivery when fetal oximetry was used as an adjunct to electronic fetal monitoring. However, Garite and colleagues found an unexplained shift in the particular indications for cesarean deliveries when fetal oximetry was used. Specifically, fetal oximetry was associated with a significant reduction in the rate of cesarean delivery among patients with a nonreassuring fetal heart rate and a concomitant increase in cesarean delivery for a diagnosis of dystocia. One proposed explanation for these results was that fetal oximetry permitted the continuation of labor complicated by a nonreassuring fetal heart rate such that dystocia could later emerge as the indication for cesarean delivery.7 This hypothesis suggests that a nonreassuring fetal heart rate in a normally oxygenated fetus can be a harbinger of impending dystocia. We did not reproduce the finding of a reduced rate of cesarean delivery in association with a nonreassuring fetal heart rate or an increased rate of cesarean delivery in association with dystocia.

Often, new technology is adopted in practice without the controlled observation necessary for objective assessment of its efficacy. The widespread adoption of intrapartum electronic fetal monitoring in the early 1970s has been cited as an example of the incorporation of technology without proof of benefit.12-14 The development of fetal oximetry held out the promise that knowledge of fetal oxygen saturation might improve understanding of fetal well-being during labor and thus reduce the rate of cesarean delivery for the indication of abnormal fetal heart rate. Our trial confirms the value of rigorous assessment of new forms of technology by showing that knowledge of fetal oxygen saturation does not lead to a significant reduction in cesarean births overall or for the indication of a nonreassuring fetal heart rate.

Presented in part at the 26th annual meeting of the Society for Maternal–Fetal Medicine, Miami, February 2, 2006.

Supported by grants (HD34116, HD36801, HD34208, HD27869, HD40545, HD21410, HD40512, HD27917, HD34136, HD40500, HD40544, HD40560, HD40485, HD27860, HD27915) from the National Institute of Child Health and Human Development.

No potential conflict of interest relevant to this article was reported.

We thank the following protocol subcommittee members for their contributions: Kenneth J. Leveno (protocol development and oversight), Steven Weiner (protocol development, data management, and statistical analysis), Allison Northen and Julia McCampbell (protocol development and coordination between clinical research centers), and Donald McIntire (study design).

Source Information

From the University of Texas Southwestern Medical Center, Dallas (S.L.B.); the National Institute of Child Health and Human Development, Bethesda, MD (C.Y.S.); George Washington University Biostatistics Center, Washington, DC (E.T.); University of Utah, Salt Lake City (M.W.V.); University of Alabama at Birmingham, Birmingham (D.J.R.); the Food and Drug Administration, Rockville, MD (S.W.); University of Texas Health Science Center, Houston (S.M.R.); University of Pittsburgh, Pittsburgh (S.N.C.); Northwestern University, Chicago (A.P.); Wayne State University, Detroit (Y.S.); Drexel University, Philadelphia (A.S.); Brown University, Providence, RI (M.C.); Case Western Reserve University, Cleveland (B.M.); University of North Carolina, Chapel Hill (J.T.); Columbia University, New York (F.M.); Wake Forest University, Winston-Salem, NC (M.H.); Ohio State University, Columbus (J.I.); and University of Texas Medical Branch, Galveston (G.A.).

Address reprint requests to Dr. Bloom at the Department of Obstetrics and Gynecology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX 75390, or at .

Other members of the National Institute of Child Health and Human Development Maternal–Fetal Medicine Units Network are listed in the Appendix.

Appendix

Other members of the National Institute of Child Health and Human Development Maternal–Fetal Medicine Units Network are as follows: University of Alabama at Birmingham: A. Northen, K. Bailey, J. Grant, S. Tate, T. Hill-Webb; Brown University: J. Tillinghast, D. Allard, P. Breault, N. Connolly, J. Silva; Case Western Reserve University: C. Milluzzi, C. Heggie, H. Ehrenberg, B. Stetzer; Columbia University: V. Pemberton, S. Bousleiman, H. Husami, V. Carmona, S. South; Drexel University: M. Talucci, M. Pollock, M. Sherman, C. Tocci, E. Selzer; George Washington University Biostatistics Center: S. Weiner, L. Leuchtenburg, F. Galbis-Reig, A. Swanson, B. Broderick; National Institute of Child Health and Human Development: S. Pagliaro, K. Howell; University of North Carolina: S. Brody, J. Granados, K. Clark, J. Mitchell, K. Dorman; Northwestern University: G. Mallett, N. Cengic, M. Huntley, T. Triplet; Ohio State University: F. Johnson, S. Fyffe, M. Landon; University of Pittsburgh: M. Cotroneo, M. Luce, H. Birkland, M. Bickus, L. Creswell-Hartman; University of Texas at Houston: M. Day, F. Ortiz, B. Figueroa, S. Shaunfield, M. Messer; University of Texas Southwestern Medical Center: J. McCampbell, L. Moseley; University of Utah: K. Anderson, B. Oshiro, F. Porter, K. Jolley, A. Guzman; Wake Forest University: M. Swain, J. Chilton, C. Leftwich, W. Davido, K. Johnson; Wayne State University: G. Norman, B. Steffy, C. Sudz, S. Blackwell.

References

References

  1. 1

    Martin JA, Hamilton BE, Sutton PD, et al. Births: final data for 2003. National vital statistics reports. Vol. 54. No. 5. Hyattsville, MD: National Center for Health Statistics, 2005.

  2. 2

    Intrapartum fetal heart rate monitoring. ACOG practice bulletin no. 70. Washington, DC: American College of Obstetricians and Gynecologists, December 2005.

  3. 3

    Hamilton BE, Martin JA, Ventura SJ, Sutton PD, Menacker F. Births: preliminary data for 2004. National vital statistics reports. Vol. 54. No. 8. Hyattsville, MD: National Center for Health Statistics, 2005.

  4. 4

    Summary minutes: meeting of the Obstetrics and Gynecology Devices Advisory Panel, open session, June 9, 2003. (Accessed October 30, 2006, at http://www.fda.gov/ohrms/dockets/ac/03/minutes/3963m1_summary%20minutes.pdf.)

  5. 5

    Yam J, Chua S, Arulkumaran S. Intrapartum fetal pulse oximetry. Part I: principles and technical issues. Obstet Gynecol Surv 2000;55:163-172
    CrossRef | Web of Science | Medline

  6. 6

    Garite TJ, Dildy GA, McNamara H, et al. A multicenter controlled trial of fetal pulse oximetry in the management of nonreassuring fetal heart rate patterns. Am J Obstet Gynecol 2000;183:1049-1058
    CrossRef | Web of Science | Medline

  7. 7

    Porreco RP, Boehm FH, Dildy GA, et al. Dystocia in nulliparous patients monitored with fetal pulse oximetry. Am J Obstet Gynecol 2004;190:113-117
    CrossRef | Web of Science | Medline

  8. 8

    American College of Obstetricians and Gynecologists. Fetal pulse oximetry: ACOG committee opinion no. 258, September 2001. Obstet Gynecol 2001;98:523-524
    CrossRef | Web of Science | Medline

  9. 9

    Lan KKG, DeMets KL. Discrete sequential boundaries for clinical trials. Biometrika 1983;70:659-663
    CrossRef | Web of Science

  10. 10

    Bloom SL, Swindle RG, McIntire DD, Leveno KJ. Fetal pulse oximetry: duration of desaturation and intrapartum outcome. Obstet Gynecol 1999;93:1036-1040
    CrossRef | Web of Science | Medline

  11. 11

    Normal labor and delivery. In: Cunningham FG, Kenneth KJ, Bloom SL, Hauth JC, Gilstrap LC III, Wenstrom KD, eds. Williams obstetrics. 22nd ed. New York: McGraw-Hill, 2005:431.

  12. 12

    Parer JT, King T. Fetal heart rate monitoring: is it salvageable? Am J Obstet Gynecol 2000;182:982-987
    CrossRef | Web of Science | Medline

  13. 13

    Parer JT. Electronic fetal heart rate monitoring: a story of survival. Obstet Gynecol Surv 2003;58:561-563
    CrossRef | Web of Science | Medline

  14. 14

    Nelson KB, Dambrosia JM, Ting TY, Grether JK. Uncertain value of electronic fetal monitoring in predicting cerebral palsy. N Engl J Med 1996;334:613-618
    Full Text | Web of Science | Medline

Citing Articles (28)

Citing Articles

  1. 1

    Michael W. Varner. 2012. Cesarean Delivery. , 406-413.
    CrossRef

  2. 2

    Barrett K. Robinson, Delicia C. Mapp, Steven L. Bloom, Dwight J. Rouse, Catherine Y. Spong, Michael W. Varner, Susan M. Ramin, Yoram Sorokin, Anthony Sciscione, Brian M. Mercer, John M. Thorp, Fergal D. Malone, Margaret Harper, Hugh Ehrenberg. (2011) Increasing Maternal Body Mass Index and Characteristics of the Second Stage of Labor. Obstetrics & Gynecology 118:6, 1309-1313
    CrossRef

  3. 3

    Alan Thevenet N. Tita, Yinglei Lai, Steven L. Bloom, Catherine Y. Spong, Michael W. Varner, Susan M. Ramin, Steve N. Caritis, William A. Grobman, Yoram Sorokin, Anthony Sciscione, Marshall W. Carpenter, Brian M. Mercer, John M. Thorp, Fergal D. Malone, Margaret Harper, Jay D. Iams. (2011) Timing of delivery and pregnancy outcomes among laboring nulliparous women. American Journal of Obstetrics and Gynecology
    CrossRef

  4. 4

    Mercedes Valverde, Alberto M. Puertas, María F. Lopez-Gallego, María P. Carrillo, María T. Aguilar, Francisco Montoya. (2011) Effectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate. European Journal of Obstetrics & Gynecology and Reproductive Biology
    CrossRef

  5. 5

    Han-Yang Chen, Suneet P. Chauhan, Cande V. Ananth, Anthony M. Vintzileos, Alfred Z. Abuhamad. (2011) Electronic fetal heart rate monitoring and its relationship to neonatal and infant mortality in the United States. American Journal of Obstetrics and Gynecology 204:6, 491.e1-491.e10
    CrossRef

  6. 6

    Dwight J. Rouse, Steven J. Weiner, Steven L. Bloom, Michael W. Varner, Catherine Y. Spong, Susan M. Ramin, Steve N. Caritis, William A. Grobman, Yoram Sorokin, Anthony Sciscione, Marshall W. Carpenter, Brian M. Mercer, John M. Thorp, Fergal D. Malone, Margaret Harper, Jay D. Iams, Garland D. Anderson. (2011) Failed Labor Induction. Obstetrics & Gynecology 117:2, Part 1, 267-272
    CrossRef

  7. 7

    Sofia A. Olivarez, Bani Maheshwari, Meghan McCarthy, Nikolaos Zacharias, Ignatia van den Veyver, Lata Casturi, Haleh Sangi-Haghpeykar, Kjersti Aagaard-Tillery. (2010) Prospective trial on obstructive sleep apnea in pregnancy and fetal heart rate monitoring. American Journal of Obstetrics and Gynecology 202:6, 552.e1-552.e7
    CrossRef

  8. 8

    Michelle E. M. H. Westerhuis, Gerard H. A. Visser, Karel G. M. Moons, Erik van Beek, Manon J. Benders, Saskia M. Bijvoet, Hendrikus J. H. M. van Dessel, Addy P. Drogtrop, Herman P. van Geijn, Giuseppe C. Graziosi, Floris Groenendaal, Jan M. M. van Lith, Jan G. Nijhuis, S. Guid Oei, Herman P. Oosterbaan, Martina M. Porath, Robbert J. P. Rijnders, Nico W. E. Schuitemaker, Louisa M. Sopacua, Ingeborg van der Tweel, Lia D. E. Wijnberger, Christine Willekes, Nicolaas P. A. Zuithoff, Ben Willem J. Mol, Anneke Kwee. (2010) Cardiotocography Plus ST Analysis of Fetal Electrocardiogram Compared With Cardiotocography Only for Intrapartum Monitoring. Obstetrics & Gynecology 115:6, 1173-1180
    CrossRef

  9. 9

    Andreas Nonnenmacher, Hartmut Hopp, Joachim Dudenhausen. (2010) Predictive value of pulse oximetry for the development of fetal acidosis. Journal of Perinatal Medicine 38:1, 83-86
    CrossRef

  10. 10

    Dwight J. Rouse, Steven J. Weiner, Steven L. Bloom, Michael W. Varner, Catherine Y. Spong, Susan M. Ramin, Steve N. Caritis, Alan M. Peaceman, Yoram Sorokin, Anthony Sciscione, Marshall W. Carpenter, Brian M. Mercer, John M. Thorp, Fergal D. Malone, Margaret Harper, Jay D. Iams, Garland D. Anderson. (2009) Second-stage labor duration in nulliparous women: relationship to maternal and perinatal outcomes. American Journal of Obstetrics and Gynecology 201:4, 357.e1-357.e7
    CrossRef

  11. 11

    Philip J. Steer. (2009) Surveillance during labour. Journal of Perinatal Medicine 37:5, 451-456
    CrossRef

  12. 12

    Lawrence D. Devoe. (2009) The future of intrapartum care: navigating the perfect storm—an obstetrician's odyssey. American Journal of Obstetrics and Gynecology 201:1, 100-104
    CrossRef

  13. 13

    A. Nonnenmacher, H. Hopp, J. Dudenhausen. (2009) Perspektiven der CTG-Anwendung während der Geburt. Der Gynäkologe 42:5, 350-360
    CrossRef

  14. 14

    M. Spaeth. (2009) Aktuelle und zukünftige Entwicklungen in der Kardiotokographie. Der Gynäkologe 42:5, 361-364
    CrossRef

  15. 15

    Christine E East. (2008) Fetal pulse oximetry during labor: theory, clinical use and the future. Pediatric Health 2:6, 787-795
    CrossRef

  16. 16

    Yoram Sorokin, Sean C Blackwell. 2008. Intrapartum evaluation of fetal well-being. , 713-724.
    CrossRef

  17. 17

    HÅKAN NORÉN, KARL G ROSÉN. (2008) INTRAPARTUM ST ANALYSIS. Fetal and Maternal Medicine Review 19:04, 325
    CrossRef

  18. 18

    D.H. Chestnut. (2008) Fetal Pulse Oximetry and Cesarean Delivery. Yearbook of Anesthesiology and Pain Management 2008, 189-190
    CrossRef

  19. 19

    &NA;. (2007) Fetal Pulse Oximetry and Cesarean Delivery. Obstetric Anesthesia Digest 27:4, 198-199
    CrossRef

  20. 20

    Christine E. East, Paul B. Colditz. (2007) Intrapartum Oximetry of the Fetus. Anesthesia & Analgesia 105:On Line Suppl., S59-S65
    CrossRef

  21. 21

    Michele C. Walsh, Jonathan M. Fanaroff. (2007) Meconium Stained Fluid: Approach to the Mother and the Baby. Clinics in Perinatology 34:4, 653-665
    CrossRef

  22. 22

    Christophe Vayssière, Eric David, Nicolas Meyer, Renaud Haberstich, Valérie Sebahoun, Emmanuel Roth, Romain Favre, Israël Nisand, Bruno Langer. (2007) A French randomized controlled trial of ST-segment analysis in a population with abnormal cardiotocograms during labor. American Journal of Obstetrics and Gynecology 197:3, 299.e1-299.e6
    CrossRef

  23. 23

    Stephen M. Cohn. (2007) Near-Infrared Spectroscopy: Potential Clinical Benefits in Surgery. Journal of the American College of Surgeons 205:2, 322-332
    CrossRef

  24. 24

    Carol Potera. (2007) In Search of Evidence Supporting Electronic Fetal Monitoring. AJN, American Journal of Nursing 107:6, 22
    CrossRef

  25. 25

    Christine E East, Lisa Begg, Paul B Colditz, Christine E East. 2007. Fetal pulse oximetry for fetal assessment in labour. .
    CrossRef

  26. 26

    (2007) Fetal Pulse Oximetry and Cesarean Delivery. New England Journal of Medicine 356:13, 1377-1378
    Full Text

  27. 27

    L.P. Shulman. (2007) Fetal Pulse Oximetry and Cesarean Delivery. Yearbook of Obstetrics, Gynecology and Women's Health 2007, 110-113
    CrossRef

  28. 28

    Greene, Michael F., . (2006) Obstetricians Still Await a Deus ex Machina. New England Journal of Medicine 355:21, 2247-2248
    Full Text

Letters