Join the 200th Anniversary Celebration

Images in Clinical Medicine

Tremor as a Cause of Pseudo–Ventricular Tachycardia

Rafael Llinas, M.D., and Galen V. Henderson, M.D.

N Engl J Med 1999; 341:1275October 21, 1999

Article

Figure 1 An 84-year-old woman with a history of falling was found on the ground unable to get up. On admission to the hospital for evaluation of syncope, she had a normal pulse and blood pressure. Examination revealed a masklike face, bradykinesia, gait instability, and a pill-rolling tremor. An electrocardiogram showed the 4-to-6-Hz tremor associated with Parkinson's disease. The QRS complexes are indicated by the arrows. Postural instability associated with Parkinson's disease was the most likely cause of the patient's falls.

Rafael Llinas, M.D.
Beth Israel Deaconess Medical Center, Boston, MA 02215

Galen V. Henderson, M.D.
Brigham and Women's Hospital, Boston, MA 02115

Citing Articles (8)

Citing Articles

  1. 1

    Javier García-Niebla, Pablo Llontop-García, Juan Ignacio Valle-Racero, Guillem Serra-Autonell, Velislav N. Batchvarov, Antonio Bayés de Luna. (2009) Technical Mistakes during the Acquisition of the Electrocardiogram. Annals of Noninvasive Electrocardiology 14:4, 389-403
    CrossRef

  2. 2

    C. C. M. Poon, M. G. Irwin. (2009) Anaesthesia for deep brain stimulation and in patients with implanted neurostimulator devices. British Journal of Anaesthesia 103:2, 152-165
    CrossRef

  3. 3

    Carmen Nogueras, Ramón Miralles, Alba Roig, Immaculada Llorach, Antoni M. Cervera. (2007) POLYPHARMACY AS PART OF COMPREHENSIVE GERIATRIC ASSESSMENT: DISCLOSURE OF FALSE DIAGNOSIS OF ATRIAL FIBRILLATION BY DRUG REVISION. Journal of the American Geriatrics Society 55:9, 1476-1478
    CrossRef

  4. 4

    Gabriel Vanerio. (2007) Tremor As a Cause of Pseudoatrial Flutter. The American Journal of Geriatric Cardiology 16:2, 106-108
    CrossRef

  5. 5

    Beste Ozben, Ahmet Kaya Bilge, Ercument Yilmaz, Kamil Adalet. (2006) Implantation of a Permanent Pacemaker in a Patient With Severe Parkinson's Disease and a Preexisting Bilateral Deep Brain Stimulator. International Heart Journal 47:5, 803-810
    CrossRef

  6. 6

    TAT W. KOH. (2005) A Case of Atypical Atrial Flutter Induced During Coronary Angiography?. Journal of Cardiovascular Electrophysiology 16:7, 798-800
    CrossRef

  7. 7

    Joshua M. Rosenow, Howard Tarkin, Elias Zias, Carmine Sorbera, Alon Mogilner. (2003) Simultaneous use of bilateral subthalamic nucleus stimulators and an implantable cardiac defibrillator. Journal of Neurosurgery 99:1, 167-169
    CrossRef

  8. 8

    A A Obwegeser, R J Uitti, M F Turk, U M Wszolek, T R Flipse, R C Smallridge, R J Witte, R E Wharen. (2001) Simultaneous thalamic deep brain stimulation and implantable cardioverter-defibrillator.. Mayo Clinic Proceedings 76:1, 87-89
    CrossRef